Type: coaxial cable.
Standard: RG 58C / U, 213 / U, 11A / U, 59B / U (MIL-C-17 US).
Field of use: indoors and in industrial areas, in protective tubes or gutters, for the transmission of high frequency signals.
Ambient temperature: -35 ° C to +80 ° C.
Standard: RG 58C / U, 213 / U, 11A / U, 59B / U (MIL-C-17 US).
Field of use: indoors and in industrial areas, in protective tubes or gutters, for the transmission of high frequency signals.
Ambient temperature: -35 ° C to +80 ° C.
Technical parameters:
RG 58 C/U | RG 213/U | RG 11 A/U | RG 59 B/U | ||
---|---|---|---|---|---|
Resistance: | 50±2 | 50±2 | 75±2 | 75±2 | Ohm |
Construction: | |||||
Conductor: | Tinned brass copper (19 x 0,18) |
7 x 0,76 |
Tinned brass copper (7 x 0,4) |
Copper-coated steel wire (0,58) |
mm |
Wire insulation: | PE | PE | PE | PE | |
Screen: | Tinned copper fabric | Copper fabric | Copper fabric | Copper fabric | |
External sheath: | PVC negru | PVC negru | PVC negru | PVC negru | |
Frequency range: | 3 | 3 | 3 | 3 | GHz |
Adjustment: | |||||
1 MHz: | 2 | 0,67 | 0,65 | 1,5 | dB/100m |
10 MHz: | 6 | 2 | 2 | 4 | dB/100m |
100 MHz: | 17 | 7,2 | 6,8 | 12 | dB/100m |
400 MHz: | 34 | 14 | 14 | 23 | dB/100m |
Capacity: | 100 | 100 | 68 | 68 | nF/km |
Propagation speed: | 67 | 67 | 67 | 67 | % |
Min. insulation resistance: | 100 | 100 | 100 | 100 | GOhm x km |
Maximum operating voltage: | 2,5 | 5,2 | 5,2 | 3,5 | kV |
Mechanical data: | |||||
Copper mass: | 19 | 76 | 56 | 23 | kg/km |
External diameter: | 5 | 10,3 | 10,3 | 6,15 | mm |
Total mass: | 37 | 160 | 142 | 55 | kg/km |