Type: cable for outdoor telephone routes with aluminum foil shielding; water penetration barriers and polyethylene jacket.
International symbol: F-2YJA2Y, A-2YF (L) 2Y StIII Bd (VDE 0816).
Rated voltage: 200 Veff / 300 V-, respectively 225 V.
Field of use: in telecommunications for data and signal transmission, in industrial installations, halls, laid in protective pipes or in the ground, protected so as not to be subjected to mechanical stresses. It cannot be used in high current installations or in power installations.
construction:
Conductor: solid copper.
Insulation: polyethylene on each bundle; petroleum gel, plastic film.
Shielding: with aluminum foil cased with plastics, spare wire.
Sheath: made of black polyethylene. The bundles are twisted four by one, and the pairs are twisted in concentric layers.
Ambient temperature: laid: -30 ° C to + 70 ° C, moving: -5 ° C to +50 ° C.
International symbol: F-2YJA2Y, A-2YF (L) 2Y StIII Bd (VDE 0816).
Rated voltage: 200 Veff / 300 V-, respectively 225 V.
Field of use: in telecommunications for data and signal transmission, in industrial installations, halls, laid in protective pipes or in the ground, protected so as not to be subjected to mechanical stresses. It cannot be used in high current installations or in power installations.
construction:
Conductor: solid copper.
Insulation: polyethylene on each bundle; petroleum gel, plastic film.
Shielding: with aluminum foil cased with plastics, spare wire.
Sheath: made of black polyethylene. The bundles are twisted four by one, and the pairs are twisted in concentric layers.
Ambient temperature: laid: -30 ° C to + 70 ° C, moving: -5 ° C to +50 ° C.
Technical parameters:
Electrical properties at 20 °C | 0,6 | 0,8 |
---|---|---|
max. conductor resistance | 130 Ohm/km | respectively 73,2 Ohm/km |
min. insulation resistance | 5 GOhm x km (F-2YJA2Y) | respectively 1,5 GOhm x km |
max. constructive capacity at 800 Hz | 52 nF/km | respectively 55 nF/km (0,8 A-2YF(L)2Y) |
Technical parameters:
Section | Sheath thickness | Copper mass | Total mass | ||
---|---|---|---|---|---|
(mm) | (mm) | (kg/km) | (kg/km) | ||
F-2YJA2Y 200 Veff/300 V- | |||||
6 | x 2 x | 0,6 | 12 | 34 | 130 |
10 | x 2 x | 0,6 | 14 | 57 | 185 |
20 | x 2 x | 0,6 | 18 | 113 | 320 |
30 | x 2 x | 0,6 | 20 | 170 | 420 |
40 | x 2 x | 0,6 | 21 | 226 | 520 |
50 | x 2 x | 0,6 | 24 | 283 | 650 |
60 | x 2 x | 0,6 | 25 | 334 | 740 |
80 | x 2 x | 0,6 | 29 | 453 | 960 |
100 | x 2 x | 0,6 | 32 | 566 | 1180 |
6 | x 2 x | 0,8 | 14 | 60 | 190 |
10 | x 2 x | 0,8 | 16 | 101 | 270 |
20 | x 2 x | 0,8 | 21 | 201 | 450 |
30 | x 2 x | 0,8 | 24 | 302 | 700 |
40 | x 2 x | 0,8 | 26 | 402 | 860 |
50 | x 2 x | 0,8 | 30 | 503 | 1100 |
60 | x 2 x | 0,8 | 31 | 604 | 1240 |
Section | Sheath thickness | Copper mass | Total mass | ||
---|---|---|---|---|---|
(mm) | (mm) | (kg/km) | (kg/km) | ||
A-2YF(L)2Y St III Bd 225 V | |||||
2 | x 2 x | 0,6 | 9 | 13 | 80 |
6 | x 2 x | 0,6 | 13 | 36 | 140 |
10 | x 2 x | 0,6 | 14 | 59 | 190 |
20 | x 2 x | 0,6 | 17 | 115 | 310 |
30 | x 2 x | 0,6 | 20 | 172 | 430 |
40 | x 2 x | 0,6 | 22 | 228 | 545 |
50 | x 2 x | 0,6 | 24 | 285 | 660 |
70 | x 2 x | 0,6 | 27 | 398 | 895 |
100 | x 2 x | 0,6 | 31 | 568 | 1225 |
150 | x 2 x | 0,6 | 37 | 852 | 1780 |
200 | x 2 x | 0,6 | 42 | 1135 | 2315 |
2 | x 2 x | 0,8 | 10 | 22 | 100 |
6 | x 2 x | 0,8 | 14 | 62 | 195 |
10 | x 2 x | 0,8 | 16 | 103 | 275 |
20 | x 2 x | 0,8 | 20 | 203 | 475 |
30 | x 2 x | 0,8 | 23 | 304 | 665 |
40 | x 2 x | 0,8 | 27 | 404 | 860 |
50 | x 2 x | 0,8 | 29 | 505 | 1050 |
70 | x 2 x | 0,8 | 33 | 706 | 1420 |
100 | x 2 x | 0,8 | 39 | 1008 | 1985 |
150 | x 2 x | 0,8 | 47 | 1512 | 2935 |
200 | x 2 x | 0,8 | 53 | 2015 | 3825 |
250 | x 2 x | 0,8 | 59 | 2520 | 4850 |